Nov 24, 2020 Leave a message

How To Adjust The Frequency Of Ultrasonic Welding Machine?

The efficiency of the ultrasonic welding machine is quite high in the operation process. The machine time has been used for a long time, and corresponding maintenance is required. For technical maintenance, the editor will tell you how to adjust the frequency of the welding machine?


1. Before tuning the resonance, you need to check whether the ultrasonic mold and the ultrasonic horn are locked, if not, they must be locked first. Also note that during the tuning period, do not let the welding head come into contact with other objects.


2. Turn on the power of the machine, and the power indicator light turns on.


3. Find the ultrasonic test switch on the machine, press it, and observe the load meter at the same time. If the pointer of the ammeter exceeds 30% of the range or the value is greater than 2 amperes, the time to press the test switch should be very short, otherwise it will To cause damage to the machine, while observing the load meter, adjust the tuning inductance at the same time, and rotate it left and right until the value on the meter is displayed at the smallest position and stops. Generally, it will be between 5 and 15 percent, with a value of 300 mA. To 900 mA.


4. For machines with card slots, their tuning inductance range is generally only 360 degrees. When the frequency of the welding head differs greatly, it needs to be re-adjusted. At this time, it is necessary to open the cover and disassemble the fixing device to re-adjust. .


You can find that the resonance adjustment operation of the ultrasonic plastic welding machine is very simple. This is because the machine itself has been equipped with this function. You only need to pay attention to the operation according to the requirements during actual operation.


Tuning notes:

1) When adjusting the tuning inductance, the size of the load meter changes, not the size of the power output, but only the degree of resonance of the generator and transducer system (the smaller the voltage, the better the resonance). (The amplitude adjustment switch can also be adjusted, but the amplitude adjustment switch cannot be adjusted when there is ultrasonic output to prevent high-voltage electric shock.)


2) When the load meter is empty, it indicates the degree of resonance; when it is loaded, it indicates the output energy.


3) During tuning, if the overload indicator light is on, immediately release the test switch, after 3 seconds, adjust the tuning inductance, and then do ultrasonic testing.


4) The correct tuning is very important. If the normal condition cannot be reached, please refer to the fault detection table. Do not use it reluctantly to avoid damage to the machine.


Send Inquiry