​Matters Needing Attention When Installing Ultrasonic Molds


Matters needing attention when installing ultrasonic molds


1. Check that the contact surface should be smooth and free of scars. If there are scars, lightly polish with metallographic sandpaper above zero. It is required to be able to smooth the defects without destroying the flatness of the contact surface.


2. Use a volatile and non-corrosive cleaning agent to clean the screws, screw holes and contact surfaces.


3. Thoroughly clean the screws, screw holes and contact surfaces.


4. All connecting screw holes should be perpendicular to the contact surface.


5. Apply a thin layer of butter or petroleum jelly on the contact surface before tightening, and be careful not to apply it to the connecting screws and screw holes.


6. Tighten the two parts carefully. According to the different specifications of the connecting screws, control the appropriate tightening torque. If possible, tighten it appropriately.


7. If you loosen the joint surface again, you should not see any scars.


8. The vibration system has a uniform amplitude when touched by hand, no strange noise, and no local severe heating.


9. After working for a period of time, the joint surface should not be oxidized or ablated. Otherwise, it means that the contact here is not good and the ultrasonic energy is lost seriously here.


10. When replacing the ultrasonic welding head, the replaced tool head needs to be processed. Wipe off the oil stains on the tool head conversion screw to avoid oxidation. Long exposure to the air will change the frequency of the tool head and reduce the use of molds and equipment. life.